ERUMI PRODUCT

UV400 HYBRID insulating film

ERUMI UV400 HYBRID combines sputtering and nanoceramic technology. Compare brightness, heat rejection and test reports for five models.

Consider it for these spaces

For homes and offices where daylight and heat gain both matter

Check before choosing

Compare visible light transmission and total solar energy rejection, then choose for the actual glass type and orientation.

Model performance and test materials

Based on ERUMI KOREA product performance tables. Check glass type and thickness, wavelengths and test methods when comparing figures. Actual effects and heating and cooling savings vary by site.

Film width:60inches

UV400 ER8080

UV400 ER8080 product photo
Visible light transmission (VLT)
80%
UV rejection (UVR)
100%
Infrared rejection (IR)
80%
Visible light reflectance (exterior) (RL)
8.9%
Visible light reflectance (interior) (RL)
8.7%
Shading coefficient (SC)
0.41
Total Solar Energy Rejected (TSER)
41.1%

Ask about a separate test report for this model during consultation.

UV400 ER5095

UV400 ER5095 product photo
Visible light transmission (VLT)
50%
UV rejection (UVR)
100%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
8.0%
Visible light reflectance (interior) (RL)
7.0%
Shading coefficient (SC)
0.59
Total Solar Energy Rejected (TSER)
53.6%
UV400 ER5095 Original test report ·20250703 (New tab)

UV400 ER4095

UV400 ER4095 product photo
Visible light transmission (VLT)
40%
UV rejection (UVR)
100%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
12.7%
Visible light reflectance (interior) (RL)
8.4%
Shading coefficient (SC)
0.52
Total Solar Energy Rejected (TSER)
59.8%
UV400 ER4095 Original test report ·20220917 (New tab)

UV400 ER3095

UV400 ER3095 product photo
Visible light transmission (VLT)
30%
UV rejection (UVR)
100%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
10.1%
Visible light reflectance (interior) (RL)
9.1%
Shading coefficient (SC)
0.48
Total Solar Energy Rejected (TSER)
64.3%
UV400 ER3095 Original test report ·20230826 (New tab)

UV400 ER1595

UV400 ER1595 product photo
Visible light transmission (VLT)
15%
UV rejection (UVR)
100%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
14.0%
Visible light reflectance (interior) (RL)
17.0%
Shading coefficient (SC)
0.41
Total Solar Energy Rejected (TSER)
70.4%
UV400 ER1595 Original test report ·20220916 (New tab)

Test reports

Select a document to zoom in on the original PDF.

UV400 ER5095 Test reports first page

UV400 ER5095

Report 20250703 · 2 pages

UV400 ER4095 Test reports first page

UV400 ER4095

Report 20220917 · 2 pages

UV400 ER3095 Test reports first page

UV400 ER3095

Report 20230826 · 2 pages

UV400 ER1595 Test reports first page

UV400 ER1595

Report 20220916 · 2 pages

From source materials to installation advice

Sources:ERUMI KOREA company brochure and supplied product performance table. Read each model's performance table and test report under its stated conditions. If an installation does not identify the model, do not attribute it to a specific product.

Discuss installation conditions and pricing

Find the right film for your space