ERUMI PRODUCT

AEGIS 70-inch insulating film

ERUMI AEGIS 70-inch film for expansive glass. Compare AEGIS 3095, 4095 and 1590 specifications and supplied test reports.

Consider it for these spaces

For large glass areas in public institutions, offices and similar spaces

Check before choosing

Check glass size and installation conditions as well as film width. The available test-report coverage differs by model.

Model performance and test materials

Based on ERUMI KOREA product performance tables. Check glass type and thickness, wavelengths and test methods when comparing figures. Actual effects and heating and cooling savings vary by site.

Film width:70inches

AEGIS 3095

AEGIS 3095 product photo
Visible light transmission (VLT)
30%
UV rejection (UVR)
99%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
5.6%
Visible light reflectance (interior) (RL)
5.1%
Shading coefficient (SC)
0.48
Total Solar Energy Rejected (TSER)
62.3%
AEGIS 3095 Original test report ·20241224 (New tab)

AEGIS 4095

AEGIS 4095 product photo
Visible light transmission (VLT)
40%
UV rejection (UVR)
99%
Infrared rejection (IR)
95%
Visible light reflectance (exterior) (RL)
6.6%
Visible light reflectance (interior) (RL)
6.5%
Shading coefficient (SC)
0.54
Total Solar Energy Rejected (TSER)
59.0%
AEGIS 4095 Original test report ·20230630 (New tab)

AEGIS 1590

AEGIS 1590 product photo
Visible light transmission (VLT)
15%
UV rejection (UVR)
99%
Infrared rejection (IR)
90%
Visible light reflectance (exterior) (RL)
31.5%
Visible light reflectance (interior) (RL)
9.6%
Shading coefficient (SC)
0.23
Total Solar Energy Rejected (TSER)
77.5%

Ask about a separate test report for this model during consultation.

Test reports

Select a document to zoom in on the original PDF.

AEGIS 3095 Test reports first page

AEGIS 3095

Report 20241224 · 2 pages

AEGIS 4095 Test reports first page

AEGIS 4095

Report 20230630 · 2 pages

From source materials to installation advice

Sources:ERUMI KOREA company brochure and latest product configuration and performance table. Read each model's performance table and test report under its stated conditions. If an installation does not identify the model, do not attribute it to a specific product.

Discuss installation conditions and pricing